Home / Revision

Electrical apprentice revision hub

Everything on Ohm & Token for electrical apprentices and students, sorted by where you are on your course: quizzes with sourced answers, a timed FICA mock, printable cheat sheets, guides, calculators and training simulators. Pick your stage.

Show:

Level 2

Level 2: health and safety, science and installation basics

City & Guilds 2365-02 and 8202-20, the EAL equivalents, and the first part of an apprenticeship (City & Guilds 5357 or EAL in England). Every course covers the same core areas, under different unit names.

Health and safety

Electrical science

Installation technology

GuideEarthing systems explained: TN-S, TN-C-S (PME) and TTHow to tell which earthing system a property has, what the letters mean, typical Ze values, and why PME supplies need extra care.GuideMain protective bonding explained: earthing vs bonding, sizes and where to connectWhat main protective bonding does, the difference between earthing and bonding, which pipes and metalwork need bonding, conductor sizes for PME (Table 54.8) and TN-S and TT supplies, where the clamps go, and when supplementary bonding is needed.GuideType B vs Type C vs Type D circuit-breakers (MCBs and RCBOs)What the B, C and D on a circuit-breaker mean, the trip currents behind each curve in BS EN 60898-1, which to use for homes, motors and transformers, how they affect maximum Zs, and how RCBOs fit in.GuideRCD types explained: AC, A, F and B, and which one you needWhat the different RCD types detect, why type AC is now restricted in BS 7671, and which type suits washing machines, heat pumps, solar inverters and EV chargers.GuideConsumer units explained: main switch, RCDs, RCBOs, SPDs and what the rules requireWhat's inside a UK consumer unit (fuse box): the main switch, RCDs, RCBOs, MCBs, SPDs and AFDDs, split-load versus all-RCBO boards, the non-combustible enclosure rule, RCD requirements in BS 7671, the labels you should see, and when replacing one is notifiable.QuizEarthing and bonding quizEarthing systems, conductor sizes and main protective bonding.QuizCircuit-breakers and RCDs quizBreaker types, trip curves and which RCD type to use.

Wiring systems and circuits

Back to the stages ↑

Level 3

Level 3: design, inspection and testing, and fault finding

City & Guilds 2365-03 and 8202-30, the EAL equivalents, and the later part of an apprenticeship. The big areas are electrical science, systems design, inspection, testing and commissioning, fault diagnosis and environmental technologies.

Electrical science: AC and three-phase

Electrical systems design

GuideHow to size a cable: current-carrying capacity, installation methods and voltage dropHow cable size is chosen under BS 7671: Ib ≤ In ≤ Iz, the twin and earth installation methods (C, 100, 101, 102, 103, A), correction factors for heat, grouping and insulation, the voltage drop check, and a worked example for an electric shower.CalculatorCable sizing calculator (twin and earth)The smallest twin and earth cable for a circuit, from BS 7671 Table 4D5 with correction factors for heat, grouping and insulation, plus voltage drop.CalculatorCable voltage drop calculatorVoltage drop along copper cable for DC, single-phase and three-phase circuits.CalculatorMaximum demand and diversity calculatorEstimate a home's maximum demand with the On-Site Guide allowances for diversity, and check it against the supply fuse.CalculatorEarth fault loop impedance (max Zs) calculatorMaximum Zs for type B, C and D circuit-breakers to BS 7671, plus R1+R2 from the cable and the fault current.Cheat sheetMaximum Zs cheat sheetMaximum measured Zs for Type B, C and D circuit-breakers and RCBOs at 230 V on one printable page.CalculatorAdiabatic equation calculatorMinimum protective conductor size from fault current and disconnection time, using S = √(I²t) / k.CalculatorFault current calculatorEarth fault and short-circuit current at the consumer unit, the end of a circuit and an appliance, and whether the breaker trips instantly.GuideSelectivity (discrimination) explained: fuses, MCBs and RCDsWhat selectivity means in BS 7671, why only the nearest device should trip, time-current curves, the 1.6:1 fuse rule, why MCBs in series often aren't selective, and how to make RCDs selective with an S type.QuizBS 7671 design and protection quizDisconnection times, protective devices and design checks.

Protection and special locations

GuideSurge protection (SPDs) explained: when BS 7671 requires them and Type 1, 2 and 3What a surge protective device does, where transient overvoltages come from, when BS 7671 Regulation 443.4.1 requires SPDs and when the owner can decline them, Type 1, 2 and 3 SPDs, and how they're installed.GuideAFDDs explained: arc fault detection devices and where BS 7671 requires themWhat an arc fault detection device does, the arcs an RCD and MCB can't see, where BS 7671:2018+A4:2026 says AFDDs shall be fitted and where they're recommended, and how they're coded on an EICR.GuideRCD types explained: AC, A, F and B, and which one you needWhat the different RCD types detect, why type AC is now restricted in BS 7671, and which type suits washing machines, heat pumps, solar inverters and EV chargers.GuideBathroom zones explained: zones 0, 1 and 2, IP ratings and what's allowed whereUK bathroom electrical zones under BS 7671 Section 701: the size of zones 0, 1 and 2, showers without a tray, IPX4 and IPX7, which lights, switches, shaver sockets and fans are allowed in each zone, the 2.5 m socket rule, RCDs and supplementary bonding.GuideEV charger installation at home: what UK rules requireWhat a home EV charge point needs in the UK: a dedicated 32 A circuit, the right RCD, protection against a broken PEN on PME supplies, cable sizing, mounting height, DC chargers at home, whether you can install your own, notifying the network operator, smart charger rules and grants.QuizSpecial locations quizBathrooms, outdoor circuits and other Part 7 locations.

Inspection, testing and commissioning

GuideR1+R2 continuity testing: how to do it and what to expectHow to test the continuity of protective conductors with the R1+R2 and wander lead methods, expected values per metre for common cables, checking polarity at the same time, and bonding continuity.GuideRing final circuit testing: the three-step continuity testHow to test a ring final circuit for continuity, what readings to expect at each step, how to spot spurs and interconnections, and how to get R1 + R2.CalculatorRing final circuit continuity calculatorCheck r1, rn and r2 end-to-end readings, get the readings to expect at each socket, and R1 + R2 for the Zs check.GuideInsulation resistance testing: test voltages, minimum values and methodHow to carry out an insulation resistance test to BS 7671: which test voltage to use, the minimum values, what to disconnect first, and what low readings usually mean.GuideEarth fault loop impedance testing: Ze, Zs and what the readings meanHow to measure Ze and Zs, why measured readings are compared with lower values than BS 7671 Table 41.3, the 0.8 rule, R1+R2 from Zs, no-trip testing on RCD circuits and prospective fault current.CalculatorRCD test and TT earth electrode calculatorMaximum RCD trip times to BS 7671, and the highest earth electrode resistance an RCD can protect on a TT system.GuideBS 7671 test values: Zs, insulation resistance, RCDs and continuityThe figures you check against when testing an installation in the UK: maximum measured Zs, insulation resistance minimums, RCD trip times, ring circuit continuity and typical Ze.Cheat sheetInspection and testing cheat sheetThe test sequence, insulation resistance values, RCD trip times and ring final checks on one page.QuizInspection and testing quizBS 7671 Part 6: test order, test values and what the readings mean.QuizInsulation resistance quizTest voltages, minimum values and what to disconnect first.SimulatorInspection and testing simulatorTest a virtual installation with an MFT, find the defects and code them. Level 1 is free.

Fault diagnosis and rectification

Environmental technologies

Certification and the rules

Back to the stages ↑

AM2 / AM2S

AM2, AM2S and AM2E: the practical assessment

The AM2 family is NET's practical assessment of competence. Apprentices on the installation and maintenance electrician standard take the AM2S as their end-point assessment. The AM2 is for some other routes, such as NVQ and JIB mature candidates, and the AM2E is for the Experienced Worker Assessment. They cover the tasks below. Section letters have changed between versions, so check your own candidate checklist from NET or your assessment centre.

Safe isolation and risk assessment

The composite installation

Inspection, testing and certification

Fault diagnosis and rectification

Applied knowledge test

Back to the stages ↑

FICA (Scotland)

FICA: the SJIB final assessment in Scotland

SJIB apprentices finish with the Final Integrated Competence Assessment. Its Section F, the Underpinning Knowledge Assessment, is 30 multiple-choice questions in 1 hour, open book, with a 70% pass mark, split across the five areas below. SJIB's candidate guidance has the official format and two mock papers with answers.

Timed mock

FICA Section F mock paper

30 questions in 1 hour, marked at the end like the real thing.

Start the mock →

BS 7671 Parts 1, 3, 4, 5 and 7 (10 questions)

BS 7671 Part 6, inspection and testing (5 questions)

Health and safety (5 questions)

Statutory regulations (5 questions)

Scottish Building Standards (5 questions)

Practise the hands-on side

Back to the stages ↑

After you qualify

After you qualify: 18th Edition, inspection and testing, and power networks

Most electricians go on to the 18th Edition award (City & Guilds 2382-26 covers BS 7671:2018+A4:2026, and centres have used it since 16 April 2026) and an inspection and testing qualification such as City & Guilds 2392-10 (fundamental inspection and initial verification) or 2391-52 (initial and periodic inspection and testing).

18th Edition, Amendment 4

Inspection, testing and EICRs

Power networks and switching

Back to the stages ↑

Course content varies between awarding bodies, colleges and versions, so your course handbook and your tutor have the final word. Written by us to help you revise. Not affiliated with City & Guilds, EAL, NET, the JIB, SJIB or SECTT. Spotted a mistake? Tell us and we'll check it against the source.