A multimeter is the most useful tool in electronics after your hands. It tells you what's really happening in a circuit, rather than what you hope is happening. Here's how to use the four functions you'll need most.
The parts of a multimeter
- The dial selects what to measure: V for voltage, A for current, Ω for resistance, and a symbol like a sound wave for continuity.
- The black probe always goes in the socket marked COM (common).
- The red probe goes in the socket marked V Ω for almost everything. Only move it to the mA or A socket when measuring current.
Some meters are "autoranging" and pick the scale for you. On manual meters, choose a range just above what you expect. For example, the 20 V range for a 9 V battery.
Measuring voltage
Voltage is measured across something, in parallel, with the circuit powered.
- Turn the dial to DC volts (V with a straight line, sometimes shown as V⎓).
- Touch the black probe to ground (the negative side) and the red probe to the point you want to measure.
- Read the display. A minus sign just means the probes are the other way round.
A fresh AA battery reads about 1.5 to 1.6 V. A 5 V USB supply should read close to 5 V, typically between 4.75 and 5.25 V.
Measuring resistance
Resistance must be measured with the power off. The meter sends its own small current through the part, and any other voltage in the circuit will give a wrong reading or could damage the meter.
For an accurate reading, measure a resistor out of the circuit, because other parts connected alongside it change the result. Don't hold both probe tips against the leads with your fingers either: your body's resistance adds to the reading, which matters for high value resistors. Compare the result with the colour bands to check it's what you think.
Checking continuity
Continuity mode beeps when the probes are connected through a very low resistance. Use it, with the power off, to check:
- That a wire or cable isn't broken.
- That a solder joint actually connects.
- Which breadboard holes are joined.
- That there's no short between power and ground before you switch on.
Measuring current
Current is the trickiest, because it's measured through the circuit, in series. You have to break the circuit and let the current flow through the meter.
- Switch off. Move the red probe to the mA socket (or the A socket for currents above a few hundred milliamps).
- Set the dial to DC current.
- Open the circuit at one point, and connect the probes either side of the gap so the current flows through the meter.
- Switch on and read.
Staying safe
- Stick to low-voltage projects (batteries, USB, bench supplies) while you're learning.
- Mains electricity can kill. Only measure it with a meter rated for mains, marked with a CAT II or higher rating for the right voltage, and only if you're trained to do so.
- Check the probe leads for cracks, and replace damaged ones.
Going deeper
Reading the accuracy specification
Meter accuracy is given as ± (% of reading + counts), where a "count" is one step of the last digit. On a 6.000 V range with ±(0.5% + 2), a reading of 5.000 V could be off by 0.5% of 5.000 (0.025 V) plus 2 counts (0.002 V), so the true value lies between 4.973 V and 5.027 V. A meter's "count" figure, such as 6,000 counts, tells you its resolution: it can show up to 5.999 on that range.
The meter changes what it measures
- Voltage: most digital meters have an input resistance around 10 MΩ. That's negligible for most circuits, but measuring across a 1 MΩ resistor in a high-impedance circuit can pull the voltage down noticeably.
- Current: the meter measures current by the voltage across an internal "shunt" resistor. This burden voltage is subtracted from your circuit. In low-voltage circuits, a few hundred millivolts of burden can make a microcontroller reset when it draws a burst of current.
True RMS
Cheaper meters measure AC by assuming the waveform is a clean sine wave. With distorted waveforms, such as the output of dimmers, motor speed controllers or switching power supplies, they can read significantly wrong. A "True RMS" meter calculates the real heating value of the waveform and stays accurate on non-sinusoidal signals, within its stated bandwidth.
Measurement categories
CAT ratings describe the voltage spikes a meter can safely survive. CAT II covers equipment plugged into sockets, CAT III the building's fixed wiring and distribution, and CAT IV the supply where it enters the building. The higher the category and voltage, the better protected the meter is against a transient arc. Cheap meters sometimes have unrealistic ratings, so for mains work, buy from a reputable brand with independent safety certification.
Other useful functions
- Diode test shows a diode's forward voltage, typically 0.5 to 0.7 V for silicon, and lights LEDs dimly.
- Capacitance modes measure capacitors out of circuit, handy for checking suspicious electrolytics.
- Min/max and hold catch brief dips, such as a battery sagging when a motor starts.
Sources