Buying guide: earth electrode and earth resistance testers

An earth resistance tester with its E, ES, S and H terminals, beside the test spikes used for a fall of potential test
Beginner
How we wrote this: we haven't tested these instruments hands-on for this guide. Every figure comes from the manufacturer's own specifications (a few via distributor copies of the datasheet), linked under Sources, checked on 22 November 2026. Models get updated and replaced, so check the current version before you buy.

An earth resistance tester measures how well an earth electrode, such as the rod at a TT installation, a lightning protection earth or a substation grid, connects to the ground around it. A low, stable reading means fault current can flow away safely. This guide explains the test methods and which tester suits which job.

Safety: disconnecting an earth electrode from a live installation removes protection. Follow the procedure in the IET's Guidance Note 3, and only work on earthing if you're competent to do so.

The short answer

  • Domestic TT installations: many electricians measure RA with their MFT's loop test. A dedicated tester such as the Kewtech KEW4105DLH adds proper 3-pole testing.
  • Commercial, lightning protection and repeated testing: a 2-, 3- and 4-pole tester such as the Megger DET4TD2.
  • Substations, telecoms and large earth systems: a full-method tester with selective and stakeless testing, such as the Fluke 1623-2 or 1625-2.
  • Testing without disconnecting or driving stakes, where there are parallel earth paths: a clamp tester such as the Megger DET14C.

Our picks: professional, mid-range and entry

Some shop links are affiliate links (Amazon UK, Tooled Up): if you buy through one we may earn a small commission, at no extra cost to you. As an Amazon Associate I earn from qualifying purchases. It never changes which products we recommend, and no shop has paid to be included.

Professional pick

Fluke 1625-2 (or 1623-2)

Substations, telecoms and big earthing systems.

  • 3- and 4-pole fall of potential, with stakes
  • 4-pole soil resistivity
  • Selective testing (one clamp and stakes) without disconnecting the electrode
  • Stakeless testing with two clamps
  • IP56 case; the -2 versions store and download results by USB

Why we picked it: Every common earth test method in one instrument. The 1625-2 adds automatic frequency control to work around interference.

Check price atAmazon UKRSFarnell

Mid-range pick

Megger DET4TD2

Contractors testing TT electrodes and lightning protection earths.

  • 2-, 3- and 4-pole tests
  • 0.01 Ω to 20 kΩ
  • 100 V CAT IV, IP54
  • Kit includes leads, stakes and carry case
  • Accuracy 2% ± 3 digits on 2-pole and 4-pole

Check price atRS

Entry pick

Kewtech KEW4105DLH

TT installations and occasional electrode tests.

  • 3- and 2-wire earth resistance, 0.01 to 2000 Ω
  • Earth voltage 0 to 300 V AC/DC
  • IP67 dust and waterproof
  • Noise rejection up to 25 V rms
  • Supplied with leads, spikes and a hard case

Check price atRS

Also consider

Megger DET14C

Stakeless testing where there are parallel earth paths.

  • Clamp-on earth resistance, 0.05 Ω to 1500 Ω
  • Elliptical jaw takes cables and tapes up to 50 mm
  • True RMS earth leakage current
  • CAT IV 600 V; DET24C adds download

Watch out: Clamp testing only works where there's a parallel return path, so it can't test a single isolated rod.

Check price atAmazon UKCPCRSFarnell

How the test methods work

3-pole fall of potential

The tester drives a current from the electrode under test (E) to a current spike (C) placed well away, and measures the voltage at a potential spike (P) in between. With P at about 62% of the distance from E to C in uniform soil, the reading is a good estimate of the electrode's resistance. Moving P a little either way and checking the reading barely changes confirms the spikes are far enough apart. The picture at the top of this guide shows the layout.

4-pole

A fourth lead removes the resistance of the test lead to the electrode from the result, which matters for very low readings. Four poles are also used for soil resistivity surveys, before a new earth system is designed.

2-pole

Measures between the electrode and a known good earth, such as a metal water pipe. It's quick, but the result includes the other earth's resistance.

Selective and stakeless

Selective testing uses a clamp around the electrode's conductor to measure that one electrode without disconnecting it from the rest of the system. Stakeless testing uses two clamps and no spikes at all, but only works where the electrode is part of a multi-earthed system.

What reading is good enough?

For a TT installation protected by an RCD, BS 7671 requires RA × IΔn ≤ 50 V. On a 30 mA RCD that would allow up to 1667 Ω, but guidance notes that readings above 200 Ω may not be stable, as ground conditions change with the seasons. Our earthing systems guide explains TT in more detail.

Before you buy: a quick checklist

  • The methods you need: 3-pole for most electrodes; 4-pole for low readings and soil resistivity.
  • Selective or stakeless testing if you can't disconnect the electrode.
  • Long enough leads in the kit to place the spikes properly.
  • Noise and interference rejection if you test near substations or railways.
  • An IP rating that suits outdoor use.

Questions people ask

Can I use my MFT instead?
For a domestic TT installation, many electricians measure RA with their MFT's earth fault loop test, as IET Guidance Note 3 allows, and some MFTs have an earth electrode test function too. A dedicated earth tester gives true 3- and 4-pole results and is better for anything beyond domestic TT.
Why does my reading change through the year?
Soil resistivity depends on moisture and temperature, so a rod in dry summer soil or frozen ground reads higher. That's why guidance favours readings with plenty of margin.