Home / Buying guides

Buying guide: how to choose a clamp meter

A clamp meter with its jaws around one conductor, measuring current without breaking the circuit
Beginner
How we wrote this: we haven't tested these instruments hands-on for this guide. Every figure comes from the manufacturer's own specifications, linked at the end. Models get discontinued and replaced, so check the current version before you buy. We don't earn anything if you buy one.

A clamp meter measures current without breaking the circuit. You open the jaws around a single conductor and read the current flowing through it. That makes it the quickest way to check a motor's running current, find an overloaded circuit, or see what a heater actually draws.

The short answer

  • For AC electrical work up to a few hundred amps, an AC true RMS clamp such as the Fluke 323 is enough.
  • If you'll meet DC, such as solar PV, batteries, vehicles or DC motor drives, you need an AC/DC clamp such as the Fluke 325. AC-only clamps can't see DC at all.
  • For big conductors, busbars and industrial work, a 1000 A clamp with a flexible probe, such as the Fluke 376 FC, reaches where rigid jaws can't.
  • For electronics and small DC currents, a mini clamp with a 2 A range, such as the UNI-T UT210E, can resolve milliamps. Keep it away from distribution boards: its safety rating is much lower.

What to look for

AC only, or AC and DC

Most clamp meters measure AC using the jaws as a current transformer. That only works on alternating current. To measure DC, the meter needs a Hall-effect sensor in the jaws. Check the specification lists a DC current range before you buy for solar, battery or automotive work.

Clamp around one conductor only

The clamp measures the net current through its jaws. Clamp around a whole flex or twin-and-earth cable and the line and neutral currents cancel, so you'll read close to zero. Separate one conductor, or use a line splitter for plug-in appliances. The same effect is useful: clamping round line and neutral together shows earth leakage, but you need a dedicated leakage clamp with milliamp resolution to read it properly.

True RMS

Many modern loads, such as LED drivers, switch-mode power supplies and variable-speed drives, draw distorted, non-sinusoidal current. An average-responding meter can misread these by a large margin. A true RMS meter measures the real heating value. All four meters below are true RMS on AC.

Jaw size and flexible probes

Check the largest conductor the jaws can close around. The Fluke 323 and 325 take conductors up to 30 mm across and the 376 FC's jaw opens to 34 mm. A flexible coil probe, such as Fluke's iFlex, wraps around large cables and busbars, and the 376 FC's measures AC up to 2500 A. Flexible probes only measure AC.

Safety rating

Clamp meters are often used at distribution boards, which is CAT III territory, or at the incoming supply, which is CAT IV. Our multimeter guide explains the categories. The same rule applies: choose a meter rated for the highest category you'll use it in, and look for marks from an independent test lab.

Resolution at low currents

A typical electrician's clamp resolves 0.01 A or 0.1 A at best, so it can't reliably tell you whether a circuit draws 20 mA or 40 mA. If you need small currents, look for a low range such as 2 A or 4 A with 1 mA resolution. With DC, press the zero button before each reading, because the Hall sensor picks up the Earth's magnetic field and drifts.

Four clamp meters compared

MeterAC currentDC currentSafety ratingNotes
Fluke 323400 A, ±2% + 5 digits (45 to 65 Hz)NoCAT III 600 V, CAT IV 300 VConductors up to 30 mm. Volts and resistance too.
Fluke 32540 A and 400 A, ±2% + 5 digits (45 to 65 Hz)40 A and 400 A, ±2% + 5 digitsCAT III 600 V, CAT IV 300 VAdds frequency, temperature and capacitance.
Fluke 376 FC999.9 A in the jaws; 2500 A with the iFlex probe999.9 A, ±2% + 5 digitsCAT III 1000 V, CAT IV 600 V34 mm jaw, inrush mode, wireless logging.
UNI-T UT210E2 A, 20 A and 100 A; 1 mA resolution on 2 A2 A, 20 A and 100 A; 2 A range ±(2% + 8 counts)CAT II 600 V, CAT III 300 VMini clamp, 17 mm jaw. Not for distribution boards.

Figures are from each manufacturer's specifications. Accuracy is stated at the lowest frequency band, and is lower at higher frequencies.

Fluke 323: simple AC clamp

True RMS AC current to 400 A, AC and DC voltage to 600 V, resistance and continuity. It's rated CAT III 600 V and CAT IV 300 V. It has no DC current range, so it's for AC electrical work only.

Fluke 325: AC and DC

Like the 323, but with AC and DC current on 40 A and 400 A ranges, plus frequency (5 to 500 Hz), contact temperature with the supplied K-type thermocouple, and capacitance. The 40 A range gives better resolution on smaller loads. A good all-round choice for electricians who also meet DC.

Fluke 376 FC: industrial and large conductors

AC and DC current to 999.9 A in the jaws, and AC to 2500 A with the flexible iFlex probe. Its ratings are CAT III 1000 V and CAT IV 600 V. It has an inrush current mode for motor starting, and a low-pass filter to give sensible readings on variable-speed drives. Readings can be sent wirelessly to Fluke's app for logging.

UNI-T UT210E: mini clamp for small currents

A small, inexpensive AC/DC clamp that's popular for automotive and electronics work, because its 2 A range resolves 1 mA. That's handy for finding a parasitic battery drain in a car. Its rating is CAT II 600 V and CAT III 300 V, which is far below what you'd want at a UK distribution board. Use it on low-voltage DC and appliance circuits, not on fixed installations.

Next steps

A clamp meter doesn't replace a multimeter, because most can't measure small voltages or resistances accurately. See our guide to choosing a multimeter, and for 4 to 20 mA instrument loops, our guide to milliamp process clamp meters.

Sources

The main references behind this guide. Numbers we worked out ourselves, such as the code outputs, come from running the code.