A multimeter is the one tool every electronics hobbyist needs. The good news is that a decent one isn't expensive. The bad news is that the listings are full of numbers that don't matter much, while the thing that matters most, safety, is easy to fake. This guide explains what to look for and compares four well-known meters.
The short answer
- For electronics and around the house, get a meter that is auto-ranging, has a microamp or milliamp range, a fast continuity beep, and a genuine CAT III 600 V rating from a known brand. The Brymen BM235 ticks every box.
- If you'll only ever check batteries, fuses and continuity, a basic meter such as the Fluke 101 is enough, but note it can't measure current.
- If you work on mains wiring for a living, you want an electrician's meter such as the Fluke 117, plus the right training.
- If you want one meter for everything, from motor drives to microamp sleep currents, the Fluke 87V is the long-standing industrial benchmark. It costs several times more than the others. A multimeter isn't a substitute for a proper voltage indicator and safe isolation procedure.
Safety first: CAT ratings
A multimeter connected to mains can see sudden voltage spikes far higher than the normal 230 V, for example when a motor switches off nearby. A cheap meter can fail violently when that happens, right next to your hand. The CAT rating tells you which kinds of circuit a meter has been designed and tested to survive.
- CAT II: things that plug into a socket, such as appliances and power tools.
- CAT III: the building's fixed wiring, such as the consumer unit (fuse box), distribution boards and hard-wired circuits.
- CAT IV: the supply coming into the building, such as the meter and the cable from the street.
The voltage after the category matters too. Fluke's guidance is to choose a meter rated for the highest category you might use it in, at a voltage at or above what you'll meet.
For battery projects at 12 V or less, the rating hardly matters. But most people eventually poke at a plug, a socket or a 230 V circuit, so buy CAT III 600 V or better and you won't need to think about it again.
Trust the label only if a lab agrees. A rating printed on the case is just a claim. Look for a mark from an independent test lab (such as UL, CSA, TÜV or Intertek ETL) on the meter itself, not just in the listing. A genuine design has large high-energy fuses, protective components and good spacing between tracks inside. Very cheap unbranded meters can carry CAT markings without that protection, and some have small glass fuses or none at all on their current inputs.
The leads count too. The UK Health and Safety Executive's guidance, GS38, says probes should have finger guards, should be marked with their CAT rating, and should have no more than 4 mm of exposed metal tip, preferably 2 mm or less, when used on live low-voltage systems. Many meters come with tip covers that do this. A meter is only as safe as its lowest-rated lead.
Features that matter for electronics
- Auto-ranging. The meter picks the range itself, so you just turn to V and read. Manual ranging is fine once you're used to it, but auto-ranging is far friendlier to start with.
- Current ranges. To measure how much your project draws, especially in sleep mode, you need a µA or mA range. Some basic meters have no current ranges at all. Check that the current inputs are fused. A good meter uses high-energy fuses on both the mA and 10 A inputs.
- Fast continuity. When you're checking a board for shorts or broken tracks, a beep that responds instantly saves a lot of time.
- Diode test. This lets you check LEDs, diodes and transistor junctions, and tell an LED's legs apart.
- Capacitance and frequency are handy extras, though not essential.
- A backlight and an auto power-off sound minor, but you'll miss them if they're missing.
Numbers that matter less than you'd think
- Counts. A 6000-count meter reads up to 5.999 V on its 6 V range, so it shows millivolts on a 3.3 V or 5 V rail. That's plenty for hobby work. 20,000 or 50,000-count meters exist, but extra digits only help if the meter's accuracy is good enough to back them up.
- Accuracy. Specs are written like ±(0.5% + 2 counts). On a 6000-count meter reading 3.300 V, that's ±(0.0165 + 0.002), or about ±0.02 V. Most hobby measurements don't need better.
- True RMS. Without it, a meter assumes AC is a perfect sine wave. That's fine for mains voltage, but gives wrong answers on dimmers, motor drives and switch-mode supplies. It's worth having, but check the frequency range: the BM235's true RMS is specified from 45 to 440 Hz, which covers mains but not audio.
Four meters compared
| Meter | Best for | Safety rating | Display | True RMS | Measures current? |
|---|---|---|---|---|---|
| Fluke 101 | Basic checks on a tight budget | CAT III 600 V | 6 V, 60 V, 600 V ranges | Not stated | No |
| Brymen BM235 | Electronics and home use, best all-rounder | CAT IV 300 V, CAT III 600 V, CAT II 1000 V | 6000 counts | Yes (45 to 440 Hz) | Yes, 600 µA to 10 A |
| Fluke 117 | Electrical work on building wiring | CAT III 600 V | 6000 counts | Yes | Yes, 6 A and 10 A ranges |
| Fluke 87V | Industrial, automotive and serious electronics work | CAT IV 600 V, CAT III 1000 V | 6000 counts, 19,999 in high-resolution mode | Yes | Yes, 0.1 µA resolution up to 10 A |
All figures are from each manufacturer's published specifications. "Not stated" means the specification doesn't say either way.
Fluke 101: the basic one
A small, simple meter from Fluke, a long-established test equipment maker, rated CAT III 600 V. It measures AC and DC volts, resistance, continuity, diodes, capacitance and frequency, with DC volts accurate to 0.5%. It has no current ranges, so it can't tell you what your project draws. That makes it a good choice for checking batteries, fuses, cables and mains sockets, but a weak one for electronics.
Brymen BM235: the best all-rounder for makers
The BM235 is also sold as the EEVblog BM235. It's a 6000-count, auto-ranging, true RMS meter with a 0.3% basic DC accuracy, current ranges from 600 µA up to 10 A, and a non-contact voltage detector. Its safety rating is unusually strong for its size: CAT IV 300 V, CAT III 600 V and CAT II 1000 V, certified to IEC/UL/EN 61010-1 and CSA. Both current inputs have proper high-energy fuses (400 mA and 11 A, both rated 1000 V). It also has a low-impedance mode, which stops "ghost voltages" on unconnected mains cables from fooling you. For electronics plus the odd job around the house, this is the one we'd pick.
Fluke 117: the electrician's choice
A true RMS, 6000-count meter rated CAT III 600 V and designed for building wiring. It adds a built-in non-contact voltage detector (VoltAlert), automatic AC/DC selection (AutoVolt), and a low-impedance mode to reject ghost voltages. DC volts are accurate to 0.5%, and it measures current on 6 A and 10 A ranges. It has no µA or mA current ranges, though, so it can't measure a microcontroller's sleep current. It's built for electricians more than electronics.
Fluke 87V: the industrial benchmark
The 87V has been a standard meter in industry for many years, and it's what many engineers and technicians carry. Its ratings are CAT IV 600 V and CAT III 1000 V. DC volts are accurate to ±(0.05% + 1 count). The percentage part is a tenth of the Fluke 117's ±(0.5% + 2 counts). Normally it shows 6000 counts, and a high-resolution mode gives 19,999 counts. It measures current from 0.1 µA resolution up to 10 A, so it covers sleep currents and motor currents alike.
It also has features the cheaper meters lack. A switchable low-pass filter gives sensible voltage and frequency readings on variable-frequency motor drives. Peak capture catches events as short as 250 µs. With the supplied thermocouple it reads temperature, and the meter covers −200 to 1090 °C excluding the probe. Fluke also sells the 87V MAX, which adds IP67 dust and water protection and a 4 m drop rating.
For hobby electronics alone it's more meter than you need. For anyone who works across electronics and electrical systems, it's the one to save up for.
What about cheap meters?
For battery-powered projects under about 30 V, an inexpensive meter is fine, and it's far better than no meter. Keep it away from mains, whatever its case says, unless it carries a mark from an independent test lab. If you buy one, check what fuses it has, and replace its leads with a properly rated set if they feel flimsy.
Next steps
Once you have a meter, our guide to using a multimeter walks through every measurement, including how to measure current without blowing the fuse.
Sources
The main references behind this guide. Numbers we worked out ourselves, such as the code outputs, come from running the code.