How the code works
The value is always in picofarads. With three digits, the first two are the value and the third is the number of zeros to add:
104= 10 followed by 4 zeros = 100,000 pF = 100 nF = 0.1 µF472= 4,700 pF = 4.7 nF220= 22 pF (no zeros added)
A third digit of 8 means multiply by 0.01, and 9 means multiply by 0.1, so 229 is 2.2 pF. Codes with one or two digits are just the value in picofarads, so 22 is 22 pF. An R marks the decimal point: 4R7 is 4.7 pF.
Tolerance letters
| Letter | Tolerance | Letter | Tolerance |
|---|---|---|---|
| B | ±0.1 pF | G | ±2% |
| C | ±0.25 pF | J | ±5% |
| D | ±0.5 pF | K | ±10% |
| F | ±1% | M | ±20% |
| Z | +80% / −20% | ||
The picofarad tolerances (B, C and D) are used on small capacitors, typically below 10 pF.
Things to watch for
- Other markings often appear nearby, such as a voltage rating or a dielectric code like X7R or C0G. Those aren't part of the value.
- Electrolytic and most larger capacitors print the value directly, for example 470 µF 25 V.
- Many surface-mount ceramic capacitors have no marking at all. Measure them with a meter that has a capacitance range, or keep them in labelled tape.
Our guide to capacitors explains the types and when to use each.