Series RLC resonance simulator

At one frequency, an inductor and a capacitor cancel each other out completely. Tune to it, sharpen the peak, and see the capacitor voltage climb far above the supply.

Advanced

Challenges

  1. Make the circuit resonate at 1 kHz (within 2%), and tune the source to it (within 1%).
  2. Get more than 10 V across the capacitor from the 1 V supply.
  3. Make a sharp filter: Q above 20.
  4. Tune the source to a half-power point, where the current is 70.7% of its peak (within 2%).

Controls

Readings

What resonance is

An inductor's reactance rises with frequency and a capacitor's falls (see the AC impedance lab). In series, their voltages are exactly opposite in phase, so they subtract. At one frequency their reactances are equal and they cancel completely. That's the resonant frequency:

f0 = 1 ÷ (2π × √(L × C))

At resonance the circuit's impedance is just R, the lowest it can be, so the current peaks at V ÷ R. Below resonance the capacitor dominates and the current leads. Above it, the inductor dominates and the current lags. Energy swaps back and forth between the inductor's magnetic field and the capacitor's electric field every cycle, and the resistor only has to make up the losses.

Q factor and bandwidth

How sharp the peak is depends on the quality factor, Q:

Q = (1 ÷ R) × √(L ÷ C)     bandwidth = f0 ÷ Q

The bandwidth is the width between the two half-power points, where the current has fallen to 70.7% of its peak (−3 dB). A high Q means a narrow, tall peak, which picks out one frequency and rejects its neighbours. That's how a radio tuner selects one station, and how many filters and oscillators work.

Voltage magnification

At resonance, the current through L and C is V ÷ R, and each of them has that current times its reactance across it. So the voltage across the capacitor, and across the inductor, is Q times the supply. With Q = 20, a 1 V signal puts 20 V across each, even though they cancel each other out as seen from the supply. In power systems this can be dangerous: a power factor correction capacitor bank can resonate with the supply's inductance at a harmonic frequency and produce damaging overvoltages, which is why detuned banks with series reactors are used (see the power factor correction lab).

Same circuit, two views

This is the same circuit as the RLC step response lab, seen another way. A high-Q circuit rings for a long time after a step, and it has a sharp resonance peak. The damping ratio there is simply 1 ÷ (2Q).

How this simulation works

The resistor, inductor and capacitor are ideal, and the source is a perfect 1 V RMS sine wave, so the readings are the exact steady-state results. The curve plots the current from a thirtieth to thirty times the resonant frequency on a logarithmic scale. Real inductors have winding resistance and real capacitors have ESR, which add to R and lower the Q. Inductor cores can also saturate at high current. The reactance calculator works out XL and XC at any frequency.

Keep exploring