How heat flows
Heat flows from the hot silicon junction, through the package, through the thermal paste and into the heatsink, then into the air. Each step has a thermal resistance in °C per watt: how many degrees hotter one side is than the other for each watt flowing. They add up like resistors in series:
TJ = TA + P × (θJC + θCS + θSA)
Rearranged, the heatsink must be no worse than θSA = (TJ − TA) / P − θJC − θCS. Pick a heatsink with a θSA lower than the answer, which means a bigger heatsink.
Where the numbers come from
- θJC is in the part's datasheet, usually in a thermal information table. Use the figure for the package you have.
- θSA is in the heatsink's datasheet. It's usually given for natural convection with the fins vertical. A fan can cut it a lot.
- Without a heatsink, use the datasheet's θJA instead of the whole sum. Be careful: θJA is measured on a specific test board, so a part on a small board or in a box will run hotter.
Better than a bigger heatsink
A linear regulator throws away the voltage difference as heat. If the dissipation is more than a watt or two, a buck converter is usually the better fix, since a typical one is 85 to 95 % efficient. Our guide to powering projects safely compares the options.