Home / Tools / Decibel calculator

Decibel calculator

Convert a gain or loss between decibels and ratios, or an absolute level between dBm, dBW, dBV, dBu, watts and volts.

  • Electronics tool
  • Runs in your browser
  • Tested 19 November 2026
  • Sources

What a decibel is

A decibel is a ratio on a logarithmic scale. For power, dB = 10 × log10(P2 / P1). Because power goes with voltage squared, the same ratio for voltage or current is dB = 20 × log10(V2 / V1). The voltage version only gives the same answer as the power version when both voltages are across the same impedance.

  • +3 dB is double the power (3.01 dB to be exact), and −3 dB is half.
  • +6 dB is double the voltage, which is four times the power.
  • +10 dB is ten times the power, and +20 dB is ten times the voltage.
  • Gains in a chain add up in decibels. An amplifier of +20 dB followed by a cable losing 3 dB gives +17 dB overall.

Absolute levels

A suffix after dB names the reference, which turns a ratio into an actual level:

Unit0 dB meansWhere you'll see it
dBm1 milliwattRF power, Wi-Fi signal strength, fibre optics
dBW1 wattTransmitters and satellite links
dBV1 volt RMSConsumer audio, where line level is −10 dBV (0.316 V)
dBu0.7746 volts RMSProfessional audio, where line level is +4 dBu (1.228 V)

0.7746 V is the voltage that puts 1 mW into 600 Ω, which is why 0 dBu equals 0 dBm only in a 600 Ω circuit. Converting between power and voltage always needs the impedance. In a 50 Ω RF system, 0 dBm is 0.224 V RMS.

Worked example. A Wi-Fi radio transmits at 20 dBm, which is 100 mW. A receiver reading −70 dBm is getting 100 picowatts, 90 dB, or a billion times, less.

Things to watch

  • The peak-to-peak voltage shown assumes a sine wave. Other waveforms have a different ratio between RMS and peak values.
  • dBi and dBd are antenna gains relative to an ideal isotropic antenna and a dipole. dBc is relative to a carrier signal. dB SPL is sound pressure relative to 20 µPa. The arithmetic is the same, but the references differ.
  • Meters often show dB readings relative to their own reference, such as 600 Ω for the dBm range on many multimeters. Check the manual before comparing numbers.

Sources

Where the formulas and figures on this page come from. We test every tool against worked examples from these before publishing.

  • IEC 60027-3: Logarithmic and related quantities, and their units (paid standard)