Heating is most of a typical UK home's energy bill, so it's where smart controls make the biggest difference. Getting the right kit depends on what boiler you have and how your current controls are wired. This guide explains it in plain English, then covers the electrical detail installers need.
Know your heating system first
| System | How to spot it | What the smart kit must control |
|---|---|---|
| Combi boiler | No hot water cylinder. Hot water heats on demand when you open a tap. | Heating only (one channel) |
| System boiler | Hot water cylinder, usually in an airing cupboard, but no cold water tank in the loft | Heating and hot water (two channels) |
| Conventional (regular) boiler | Cylinder plus a cold water storage tank in the loft | Heating and hot water (two channels) |
| Heat pump | Outdoor unit, usually with a cylinder | Often its own controller: check the smart kit supports your model |
Systems with a cylinder need a smart thermostat kit that also controls hot water. tado, for example, says its Wireless Smart Thermostat X controls hot water cylinder schedules, while its Wired version is for heating only.
Smart thermostats
A smart thermostat does what a programmable room thermostat does, plus app control, smarter scheduling, and features such as geofencing (heating down when everyone's out), open-window detection and weather-based pre-heating. Some of those features are in optional subscriptions: tado's AI Assist and Hive+ are examples.
Wired or wireless?
- Wired: replaces an existing wired wall thermostat, using the same cable back to the boiler or wiring centre. Usually the simplest swap.
- Wireless: a receiver goes next to the boiler (wired to the boiler's thermostat terminals or the wiring centre) and the thermostat itself sits on a wall or a stand anywhere. Good where there's no existing thermostat cable.
Relay (on/off) or OpenTherm
Most UK thermostats simply switch the boiler on or off, like a relay. The boiler then runs at whatever flow temperature it's set to until the room is warm enough, and switches off.
OpenTherm is a two-wire digital link between the thermostat and a compatible boiler. Instead of on/off, the thermostat tells the boiler how much heat is needed, so the boiler can turn its output down (modulate) and run at a lower flow temperature for longer. Lower return temperatures let a condensing boiler condense more, which is where the efficiency gain comes from. Hive says its OpenTherm mode works only with compatible combi boilers and single-zone systems; tado says Smart Thermostat X works with relay or OpenTherm boilers. Your boiler manual will say whether it supports OpenTherm (some brands use their own protocol instead).
Smart radiator valves (TRVs)
A smart radiator valve replaces the thermostatic head on a radiator. It lets each room have its own schedule and temperature, so spare rooms aren't heated all day. Fitting is usually a screw-on job: Hive includes valve adaptors for M30, M28 and Danfoss RA valve bodies, for example. You don't drain the system to swap a head, only the valve body if that's being replaced.
To save energy, the valves and the boiler need to work together: when a room calls for heat, the system should fire the boiler. Most brands do this when their valves and thermostat are on the same system.
Hubs and connectivity
Smart heating kits normally include or need a hub or bridge that connects them to the internet:
- Hive devices use Zigbee and need a Hive Hub for app control. Hive says the thermostat keeps running your schedules if the internet drops.
- tado X uses Thread and Matter. It needs a Thread border router: tado's Bridge X, which comes in some starter kits, or a compatible third-party device such as an Apple HomePod mini. tado says its Wireless Smart Thermostat X starter kit has a border router built in.
- Netatmo's Smart Thermostat (no longer sold) used a relay next to the boiler, linked wirelessly to the thermostat.
Google Nest in the UK
Google ended support for the 1st and 2nd generation Nest Learning Thermostats, including the 2014 European version, on 25 October 2025: they no longer connect to the Nest or Home apps, though their on-device schedules keep working. Google also said in April 2025 that it wouldn't launch new Nest thermostats in Europe. If you're buying new in the UK, look at other brands.
The rules: Boiler Plus in England
Since 6 April 2018, when a gas boiler is installed in an existing home in England, it must have time and temperature controls if there aren't working ones already. A replacement combi boiler must also have one extra energy-saving measure from a list: flue gas heat recovery, weather compensation, load compensation, or a smart thermostat with automation and optimisation. That's one reason installers often fit a smart thermostat with a new combi. The government's Boiler Plus policy paper sets these out; the current requirements are in Approved Document L.
Installing safely
- Many boiler thermostat connections and wiring centres carry 230 V, even where the thermostat itself is battery powered. Isolate the boiler and heating controls (usually a fused spur), prove dead, and follow the maker's wiring diagram.
- Check the switching rating. Netatmo's Smart Thermostat, for example, specified switching through a dry (volt-free) contact rated at 0.5 A at 220 to 240 V, so it can switch a boiler's thermostat input but not a pump or heater directly.
- Opening the boiler casing can expose gas components. Thermostat terminals are normally reachable without that, but if the wiring is inside the sealed part of the boiler, stop and use a Gas Safe registered engineer.
- If you remove an old wiring arrangement such as a Honeywell SmartFit system, Hive says the old controls including electrically operated valves must be removed first.
Going deeper
Y-plan and S-plan wiring
Systems with a cylinder use motorised valves. A Y-plan has one three-port mid-position valve shared between heating and hot water. An S-plan has two two-port valves, one per circuit, each with a microswitch that brings the boiler and pump on when the valve opens. Both use a wiring centre (a junction box with numbered terminals) where the programmer, room thermostat, cylinder thermostat and valves meet. A two-channel smart receiver replaces the programmer's heating and hot water outputs, and the room thermostat function moves into the smart thermostat. Wire to the system's existing diagram, which for most UK motorised valve systems follows the valve maker's standard terminal numbering.
Why modulation saves energy
A condensing boiler recovers latent heat from water vapour in the flue gas only when the return water is below about 55 °C (the flue gas dew point). With on/off control and a high flow temperature, return water often stays above that. Modulating control (OpenTherm, load or weather compensation) keeps the flow, and therefore return, temperature lower for longer runs, so the boiler spends more time condensing and cycles less often. Short cycling also wastes energy in each warm-up.
Weather and load compensation
Weather compensation sets flow temperature from outdoor temperature using a heat curve. Load compensation sets it from how far the room is from its target. Both are listed options under Boiler Plus for combis, and both need a compatible boiler and sensor.
Sources
The main references behind this guide. Numbers we worked out ourselves, such as the code outputs, come from running the code.
- tado press release: tado X launches in the UK (Bridge X, OpenTherm and relay, Thread border router)
- tado press release: Smart Thermostat X (2nd gen), 2 September 2026
- tado: Smart Thermostat X installation help
- Hive: Hive Thermostat (OpenTherm, compatibility and hub FAQs)
- Hive: Hive Radiator Valve (valve adaptors, hub requirement)
- Netatmo: Smart Thermostat, compatibility and switching limits
- Google Nest Help: End of support for Nest Learning Thermostats (1st and 2nd gen)
- 9to5Google (25 April 2025): Google won't launch new Nest thermostats in Europe
- BEIS: Boiler Plus final policy and consultation response (2017)